Metal Recovery Ion Exchange System
Effluent Graph for Copper Recovery

This system is from a still existing( 2007, 15years and still running) printed circuit manufacturer in the Los Angeles area. This data is from 1996 when copper limits were 0.5 ppm.  There was no attempt to increase the systems efficiency.  Newer systems can run from non-detectable to 10 ppb depending on the type of waste treated and optimization. This is a Remco Engineering MRIX system with older software and control parameters.

This system was in operation for three and one half years before the start of this graph. This data is from the normal day to day records of this operation. Three samples are taken each day and analyzed on an AA. They are averaged and the average and range (high minus low) are reported. Note that even then, the system generally ran under 100 ppb with no special effort to optimize operating parameters. (Full screen on 1024x768 monitor)