LINKS -
DOWNLOAD
OUR LITERATURE
WATER
TREATMENT
BOILER
WATER TREATMENT
REVERSE
OSMOSIS
ION
EXCHANGE
WASTEWATER
TREATMENT
WHOLE
HOUSE SYSTEMS
FILTRATION
SITE
INDEX
HOME
PAGE
SYSTEM
CONTROLS
WHERE'S
REMCO?
|
THE
GOLD RECOVERY MODULE

The Remco Engineering Gold recovery module puts money in your
pocket, not in your drain. If you don't have an ion exchange recovery
module on your Gold rinse, you are rinsing money down the drain.
Many shops have plate-out units on their Gold dragouts, but Gold
is still rinsed down the drain. Plate out units only work down
to 50-200 ppm. Ion exchange systems work down to 0-10 parts per
BILLION. Our system uses multiple columns to provide a long path
length and a long residence time in a compact unit.
Our system features its own containment system in case there is
a leak in the connections so no Gold is dumped on the floor. The
columns are easily emptied and refilled with new resin. Used resin
is sent to a reclaimer to be burned. By using 3 small columns
in series, only the first column needs to fill before reclaiming.
This minimizes your Gold inventory awaiting reclaim. After the
first column is emptied of resin, it is refilled and moved to
the end of the line to be the final polishing filter.
The system mounts directly to the top flange of the rinse tank.
We recommend you use either a small sump pump and recirculate
the rinse through the columns at about 0.5 gpm, or you can use
our optional level control to operate the pump to feed solution
from the rinse to the columns and down the drain.
GOLD RECLAIM MODULE SPECIFICATIONS
Operational Range:
pH......................................................................2-12
Flow rate range:...............................................0-.5
GPM
Pump, (customer supplied)
Centrifugal........................................................0.5
gpm
Tubing...............................................................0-0.5
gpm
Power................................................................1/6hp
Power Requirements: Pump dependent
|